< Back to Generators

Aston

PremiAir Hire have a wide range of silenced bio diesel powered, fuel efficient generators ranging from 5kva single phase units through to 1250kva 3 phase sets, all manufactured in accordance with strict European standards.

We offer a variety of configurations , including trailer mount, skid mount & 20ft containerised sets, super silenced, synchronising capability, BMA & MDG15 Mine specified units.

No matter what your needs or applications, PremiAir will have a solution to meet your demands.

DESCRIPTION

PremiAir Hire have a wide range of silenced bio diesel powered, fuel efficient generators ranging from 5kva single phase units through to 1250kva 3 phase sets, all manufactured in accordance with strict European standards.

We offer a variety of configurations , including trailer mount, skid mount & 20ft containerised sets, super silenced, synchronising capability, BMA & MDG15 Mine specified units.

No matter what your needs or applications, PremiAir will have a solution to meet your demands.


PRODUCT DETAILS

Rated Output PS(kW) Dimensions (LxWxH) Wet Weight Name Prime Engine Make Engine Model No. of Cylinder Cooling Type Total Displacement (CU) Tank Capacity (L) Fuel Consumption (L/H @ 75%) Lublicating Oil Capacity (L) Cooling Water Capacity (L) Battery Capacity (5hrs) Sound Level (dBA) Specurl Website Link
15.6 (11.5) 1,880 X 790 X 1,200 751 XL 13-KU 10.5kVA Kubota D1503DK3A 3 Swirl Chamber 1.499 58 3.7 8.0 8.5 80D26R(55) 56 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL13-KU.pdf https://myntgroup.com.au/xl/xl-13-ku/
26 (19.1) 1,950 X 830 X 1,230 860 XL 25-KU 20kVA Kubota V2403DK3A 4 Direct Injection,Turbo charged 2.434 70 4.0 9.5 7.0 80D26R(55) 59 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL25-KU.pdf https://myntgroup.com.au/xl/xl-25-ku/
51.7 (38.0) 2,270 X 1,000 X 1,470 1206 XL 45-KU 38kVA Kubota V3800DDIDTDK2B 4 Direct Injection,Turbo charged 3.769 100 6.4 13.2 11.0 80D26R(55) 57 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL45-KU.pdf https://myntgroup.com.au/xl/xl-45-ku/
65.4 (48.1) 2,490 X 1,010 X 1,470 1474 XL 60-IS 50kVA Isuzu BBD4BG1T 4 Direct Injection,Turbo charged 4.329 135 8.6 14.0 15.0 80D26R(55) 59 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL60-IS.pdf https://myntgroup.com.au/xl/xl-60-is/
100 (73.6) 3,000 X 1,150 X 1,700 2159 XL 100-IS 80kVA Isuzu DDD6BG1T 6 Direct Injection,Turbo charged 6.494 225 14.5 18.0 24.0 95D31R(64) 61 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL100-IS.pdf https://myntgroup.com.au/xl/xl-100-is/
131 (96.3) 3,390 X 1,220 X 1,770 2626 XL 125-HI 100kVA Hino J08CDUP 6 Direct Injection,Turbo charged 7.961 250 16.4 24.5 22.0 95D31R(64) 63 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL125-HI.pdf https://myntgroup.com.au/xl/xl-125-hi/
160(118) 3,390 X 1,220 X 1,480 2756 XL 150-HI 125kVA Hino J08CDUD 6 Direct Injection,Turbo charged Intercooled 7.961 250 19.4 24.5 22.0 95D31R(64) 63 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL150-HI.pdf https://myntgroup.com.au/xl/xl-150-hi/
246(181) 4,100 X 1,460 X 2,050 4230 XL 220-KO 200kVA Komatsu SAA6D125E-2-B 6 Direct Injection,Turbo charged Intercooled 11.040 390 32.3 42.0 46.4 170F51 (x2) 65 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL220-KO.pdf https://myntgroup.com.au/xl/xl-220-ko/
315(232) 4,300 X 1,560 X 2,060 4899 XL 300-KO 270kVA Komatsu SAA6D125ED2DB 6 Direct Injection,Turbo charged Intercooled 11.040 490 43.1 62.0 43.5 170F51(120) 66 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL300-KO.pdf https://myntgroup.com.au/xl/xl-300-ko/
421(310) 4,550 X 1,560 X 2,340 6300 XL 400-KO 350kVA Komatsu SA6D140ED3DB 6 Direct Injection,Turbo charged Intercooled 15.240 490 56.6 79.0 69.0 225H52(176) 67 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL400-KO.pdf https://myntgroup.com.au/xl/xl-300-ko/
519(382) 5,010 x 1,700 x 2,250 7400 XL 500-KO 450kVA Komatsu SAA6D140ED3DB 6 Direct Injection,Turbo charged Intercooled 15.240 490 69.2 91.5 91.5 225H52(176) 69 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL500-KO.pdf https://myntgroup.com.au/xl/xl-500-ko/
669 (485) 5,050 X 1,760 X 2,700 8745 XL 610-KO 555kVA Komatsu SA6D170-A-1 6 Direct Injection,Turbo charged Intercooled 23.150 490 101.2 119.0 141.0 225H52(176) x2 69 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL610-KO.pdf https://myntgroup.com.au/xl/xl-610-ko/
15.6(11.5) 1,790 X 810 X 1,410 842 XL 13-KU-BT 11kVA Kubota D1503DK3A 3 Swirl Chamber 1.000 95 2.4 7.0 6.0 80D26R(55) 55 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL13-KU-BT.pdf https://myntgroup.com.au/xl-bt/xl-13-ku-bt/
26(19.1) 1,950 X 830 X 1,500 1070 XL 25-KU-BT 20kVA Kubota V2403DK3A 4 Swirl Chamber 2.000 145 4.0 10.0 7.0 80D26R(55) 59 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL25-KU-BT.pdf https://myntgroup.com.au/xl-bt/xl-25-ku-bt/
51.7(38.0) 2,270 X 1,050 X 1,810 1582 XL 45-KU-BT 37kVA Kubota V3800DDIDTDK2B 4 Direct Injection,Turbo charged 4.000 325 6.4 13.0 11.0 80D26R(55) 56 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL45-KU-BT.pdf https://myntgroup.com.au/xl-bt/xl-45-ku-bt/
65.4(48.1) 2,480 X 1,180 X 1,740 1893 XL 60-IS-BT 50kVA Isuzu BBD4BG1T 4 Direct Injection,Turbo charged 4.000 400 8.6 14.0 15.0 80D26R(55) 59 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL60-IS-BT.pdf https://myntgroup.com.au/xl-bt/xl-60-is-bt/
131(96.3) 2,930 X 1,250 X 2,060 2968 XL 100-IS-BT 80kVA Isuzu BID4HK1X 4 Direct Injection,Turbo charged Intercooled 5.000 740 13.2 21.0 22.0 170F51(120) 60 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL100-IS-BT.pdf https://myntgroup.com.au/xl-bt/xl-100-is-bt/
131(96.3) 2,930 X 1,250 X 2,680 3018 XL 125-IS-BT 100kVA Isuzu BID4HK1X 4 Direct Injection,Turbo charged Intercooled 5.000 740 16.0 21.0 22.0 170F51(120) 60 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL125-IS-BT.pdf https://myntgroup.com.au/xl-bt/xl-125-is-bt/
162(119) 3,500 X 1,250 X 2,150 3758 XL 150-IS-BT 125kVA Isuzu BID6HK1X 6 Direct Injection,Turbo charged Intercooled 8.000 815 22.2 38.0 28.0 95D31R(64) 64 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL150-IS-BT.pdf https://myntgroup.com.au/xl-bt/xl-150-is-bt/
246(181) 3,550 x 1,300 x 2,150 4550 XL 220-MI-BT 200kVA Mitsubishi 6D24DTLE2B 6 Direct Injection,Turbo charged Intercooled 12.000 980 31.8 37.0 29.0 170F51(120) x2 66 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/XL220-MI-BT.pdf https://myntgroup.com.au/xl-bt/xl-220-mi-bt/
26(19.1) 1,970 X 920 X 1,600 954 WH 25-IS 20kVA Isuzu AA4LE1 4 Swirl Chamber 2.179 75 3.7 8.0 8.5 80D26R(55) 51 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/WH25-IS.pdf https://myntgroup.com.au/wh/wh-25-is/
51.7(38.0) 2,270 X 1,050 X 1,550 1462 WH 45-KU 37kVA Kubota V3800DITK2B 4 Direct Injection,Turbo charged 4.000 165 6.5 13.0 11.0 80D26R(55) 51 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/WH45-KU.pdf https://myntgroup.com.au/wh/wh-45-ku/
65(48.1) 2,490 X 1,140 X 1,550 1670 WH 60-IS 50kVA Isuzu BB4BG1T 4 Direct Injection,Turbo charged 4.000 170 8.6 14.0 15.0 80D26R(55) 55 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/WH60-IS.pdf https://myntgroup.com.au/wh/wh-60-is/
100(73.6) 3,100 X 1,210 X 1,800 2442 WH 100-IS 80kVA Isuzu DD,6BG1T 6 Direct Injection,Turbo charged 6.000 225 14.5 18.0 24.0 95D31R(64) 54 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/WH100-IS.pdf https://myntgroup.com.au/wh/wh-100-is/
160(118) 3,600 x 1,250 x 1,930 3200 WH 150-HI 125kVA Hino J08C,UD 6 Direct Injection,Turbo charged Intercooled 8.000 265 19.4 25.0 22.0 95D31R(64) 55 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/WH150-HI.pdf https://myntgroup.com.au/wh/wh-150-hi/
26(19.1) 1,970 X 920 X 1,600 1199 WH 25-KU-BT 20kVA Kubota V2403DK3A 4 Swirl Chamber 2.000 145 4.0 10.0 7.0 80D26R(55) 51 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/WH25-KU-BT.pdf https://myntgroup.com.au/wh-bt/wh-25-ku-bt/
65.4(48.1) 1,870 x 860 x 1,590 1590 WH 45-KU-BT 37kVA Kubota V3800DDIDTDK2B 4 Direct Injection,Turbo charged 4.000 325 6.4 13.0 11.0 80D26R(55) 56 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/WH45-KU-BT.pdf https://myntgroup.com.au/wh-bt/wh-45-ku-bt/
65.4(48.1) 2,490 X 1,140 X 1,880 1987 WH 60-IS-BT 50kVA Isuzu BBD4BG1T 4 Direct Injection,Turbo charged 4.000 400 8.6 14.0 15.0 80D26R(55 54 https://myntgroup.com.au/wp-content/uploads/SpecSheet/Aston/WH60-IS-BT.pdf https://myntgroup.com.au/wh-bt/wh-60-is-bt/


ADDITIONAL DETAILS

Accessories are available for these products.

  • Single Phase Leads (10 Amp / 240 V)
  • Single Phase Leads (15 Amp / 240 V)
  • Three Phase Leads – (32 Amp)
  • Three Phase Leads – (50 Amp)
  • Cable sets – (35 mm – 240 m) [four core & earth]
  • Single Distribution Board
  • 3 Phase Distribution Board
  • Cable Covers (2 & 5 Cable Units)
  • Wheel Chair Accessible Cable Covers
  • PowerLock Cable Sets
  • Joiner Boxes